Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
2.
Laboratory Medicine Online ; : 182-188, 2017.
Article in English | WPRIM | ID: wpr-51171

ABSTRACT

BACKGROUND: The use of point-of-care (POC) devices for evaluating HbA1c is increasing; accordingly, comparisons between these devices and central laboratory methods are important. In the present study, we evaluated the analytical performance of the cobas b 101 analyzer for POC HbA1c testing. METHODS: The analytical quality of the cobas b 101 system was assessed based on repeatability, within-laboratory precision, linearity, and lot-to-lot reproducibility. Two specimen types, i.e., EDTA whole blood and capillary blood, were examined using the cobas b 101 system and the Variant II Turbo instrument. RESULTS: The coefficient of variation for within laboratory precision was 5.22% for a normal HbA1c level and 2.56% for a higher HbA1c level. The method showed good linearity, with a coefficient of correlation of 0.990. In a comparison of two different HbA1c disk lots, a strong correlation (r=0.986) and a mean %difference of −2.9% were observed. The cobas b 101 results using EDTA whole blood were strongly correlated with the Variant II Turbo results (r=0.958), with a mean %difference of 0.8%; the cobas b 101 results using capillary blood were strongly correlated with the Variant II Turbo results, using EDTA whole blood (r=0.976), with a mean %difference of 2.0%. A comparison between HbA1c levels in EDTA whole blood and capillary blood obtained using the cobas b 101 showed a strong correlation (r=0.985) and a mean %difference of 1.3%. CONCLUSIONS: The cobas b 101 analyzer is convenient for the measurement of HbA1c levels for diabetes management.


Subject(s)
Capillaries , Edetic Acid , Methods , Point-of-Care Systems , Point-of-Care Testing
3.
Annals of Clinical Microbiology ; : 74-79, 2017.
Article in English | WPRIM | ID: wpr-50238

ABSTRACT

Psychrobacter sanguinis has been described as a Gram-negative, aerobic coccobacilli originally isolated from environments and seaweed samples. To date, 6 cases of P. sanguinis infection have been reported. A 53-year-old male was admitted with a generalized tonic seizure lasting for 1 minute with loss of consciousness and a mild fever of 37.8℃. A Gram stain revealed Gram-negative, small, and coccobacilli-shaped bacteria on blood culture. Automated microbiology analyzer identification using the BD BACTEC FX (BD Diagnostics, Germany) and VITEK2 (bioMérieux, France) systems indicated the presence of Methylobacterium spp., Aeromonas salmonicida, and the Moraxella group with low discrimination. The GenBank Basic Local Alignment Search Tool and an Ez-Taxon database search revealed that the 16S rRNA gene sequence of the isolate showed 99.30% and 99.88% homology to 859 base-pairs of the corresponding sequences of P. sanguinis, respectively (GenBank accession numbers JX501674.1 and HM212667.1). To the best of our knowledge, this is the first human case of P. sanguinis bacteremia in Korea. It is notable that we identified a case based on blood specimens that previously had been misidentified by a commercially automated identification analyzer. We utilized 16S rRNA gene sequencing as a secondary method for correctly identifying this microorganism.


Subject(s)
Humans , Male , Middle Aged , Aeromonas salmonicida , Bacteremia , Bacteria , Databases, Nucleic Acid , Discrimination, Psychological , Fever , Genes, rRNA , Korea , Methods , Methylobacterium , Moraxella , Psychrobacter , RNA, Ribosomal, 16S , Seaweed , Seizures , Unconsciousness
SELECTION OF CITATIONS
SEARCH DETAIL